Transformer & Mobile Substation · 15 kVA → 1,120 MVA

60-Week Wait? Not With Us.

Power and GSU transformers to 1,120 MVA / 750 kV in 16–20 weeks. Pad-mounted and dry-type distribution transformers in ~8 weeks. Complete mobile substations on truck, container, or E-House — built in ~20 weeks and deployed in hours-to-days on arrival. 800 VDC-native Solid State Transformers for AI data centers. Built on IEC 60076 / IEEE C57 / AS 60076 / GOST certified lines, with short-circuit and FR3 natural-ester options — shipping to US, Canadian, Australian, and European utilities.

24-Hour Quote · No Spec Sheet Needed

1,120 MVA

Max Power Transformer

750 kV

Voltage Class

25 MVA

Dry-Type · 110 kV

80 MVA

Mobile Substation · 345 kV

REF · 01Track Record · Transformers

Already Engineered. Already Energizing.

Tarxon's role is engineering, procurement, solution architecture, system integration, and field execution. The fleet below is what our manufacturing partner network has already deployed across North America.

01 · STAT
30+
NA · 2024 → 2026

Power Transformers

Up to 345 kV · GSU & main step-up

02 · STAT
270+
NA · 2024 → 2026

Distribution Units

Pad-mount · Dry-type · Isolation

03 · STAT
5,000+MVA
NA · 2024 → 2026

Installed Capacity

Across NA AIDC, utility & industrial sites

04 · STAT
100%
NA · 2024 → 2026

Standards Compliant

IEEE C57 / C37 · UL Listed · ISO 9001

Counts reflect lines we have engineered, witnessed, and shipped through partner factories to NA sites.

REF · 02Reference Fleet · By Product Category

Top-Tier Production Lines, Already on the Ground

Top-tier production lines we draw on for new Tarxon projects. Voltage, capacity, and unit counts as deployed across North America.

Project list is partial. Additional NDA-protected references available on request.

Power Transformer (Oil-Immersed)

Power Transformer (Oil-Immersed)

Large-capacity oil-immersed power transformers built on the same production lines that deliver to US, Australian, and European utilities — ISO 9001/14001/45001/50001 certified plants, short-circuit-tested to IEC 60076 and IEEE C57.12.00. Benchmark units include 150 MVA / 345 kV uniform-insulation OLTC (525 kV AC withstand, 1,300 kV BIL) and 360 MVA / 330 kV high-efficiency autotransformers for renewable integration. Available in mineral oil and K-class natural ester (FR3) fluid with carbon emissions 1/64 of mineral oil and 98% biodegradability. Typical delivery 16–20 weeks — compared with 60+ weeks on the open market.

Up to 1,120 MVA, 750 kV class
525 kV AC withstand / 1,300 kV BIL proven
Mineral oil or FR3 natural ester (K-class)
ONAN / ONAF / OFAF / ODAF cooling
On-load tap changers (OLTC) up to ±16 steps
1.3× continuous overload on ester-insulated units
IEC 60076 / IEEE C57 / AS 60076 / GOST tested
Short-circuit withstand type test included
Exported to US, Canada, Mexico, EU, ANZ, LATAM
DGA, PD, and fiber-optic winding temp monitoring
Pad-mounted Transformer

Pad-mounted Transformer

Tamper-resistant, ground-level transformers for underground distribution, data center campus power, commercial and mixed-use developments, and utility-scale solar collector circuits. Built to IEEE C57.12.28 (painting and coating) and UL 1561 with single-phase ratings to 250 kVA and three-phase ratings to 10 MVA at 34.5–66 kV. Loop-feed (LBOR-VFI compatible) and radial-feed arrangements; dead-front and live-front bushings; mineral oil or FR3 ester fluid. The fastest-to-site transformer class — typical delivery ~8 weeks.

75 kVA – 10 MVA
Up to 34.5 kV (three-phase)
Loop & radial feed, dead-front / live-front
UL 1561 / IEEE C57.12.28 / C57.12.34 listed
Tamper-resistant pentahead locking
High-efficiency grain-oriented or amorphous core
FR3 natural ester (K-class) available
Stainless or polymer-coated enclosure options
LBOR-VFI / elbow surge arrester ready
Seismic-qualified base on request
Dry Type Transformer

Dry Type Transformer

Cast-resin and VPI dry-type transformers for indoor, offshore, and fire-sensitive installations. Built on the production line that produced China’s first 110 kV three-phase epoxy resin cast dry-type power transformer, with CE, UL, ASTA (E3/C3/F1 climate-environment-fire class), DEKRA, and salt-spray / anti-seismic certifications. Ratings run from 15 kVA distribution units up to 25 MVA / 110 kV power-class dry transformers — with dedicated variants for offshore wind nacelles, hydrogen electrolysis rectifier duty (12-pulse, 7.5 MVA), and data center white space.

15 kVA – 25 MVA
Up to 110 kV class (industry-leading for dry)
Cast resin or VPI (Vacuum Pressure Impregnated)
Partial discharge ≤ 5 pC
Temperature rise classes F / H, 90K–125K
Climate / Environmental / Fire: E3 / C3 / F1
UL, CE, ASTA, DEKRA certified
Nomex® insulated VPI isolation variant
Amorphous core option for low loss
Offshore wind, rectifier, and EV charging variants
GSU Transformer (Generator Step-Up)

GSU Transformer (Generator Step-Up)

Generator step-up transformers matched to gas turbines, steam turbines, reciprocating engines, and inverter-based renewables. Representative builds include a 360 MVA / 330 kV Tier-II-efficient OLTC autotransformer and 5 MW / 35 kV PV step-up blocks that integrate PCS, transformer, MV ring-main unit, and LV distribution in a single skid. Engineered for fast-start duty cycles, unbalanced harmonic load from IGBT inverters, and the demanding thermal profiles of peaker and combined-cycle plants. Typical delivery 16–20 weeks.

20 MVA – 400 MVA
Up to 345 kV HV class
Matched to turbine or inverter output
Fast-start / cyclic duty rated
On-load tap changers (OLTC)
Low-noise amorphous or grain-oriented core
Enhanced short-circuit strength (composite field design)
Lightning & switching impulse type tested
IEEE C57 / IEC 60076 compliant
Online monitoring / remote SCADA ready
Mobile Substation — Truck, Container & E-House

Mobile Substation — Truck, Container & E-House

A complete substation on wheels, in a container, or in a factory-assembled E-House. Power transformer, HV switching (GIS or AIS), MV distribution, protection, control, and SCADA factory-integrated and tested to IEC 62271-202 / IEEE C37.121. Because every unit is engineered to North American utility specifications — including layout review, IEEE/UL approvals, and factory acceptance testing — typical build time is ~20 weeks from PO to ship. The payoff comes on site: with everything pre-integrated and factory-tested, on-truck units energize within hours of arrival, and containerized / E-House platforms commission in days rather than the weeks-to-months a stick-built substation would require. Use as an interim GSU for mobile generator arrays, as a bridge substation during utility outage or transformer rebuild, or as a permanent relocatable substation.

Up to 80 MVA · up to 345 kV class
~20 wk build · on-site deploy in hours (truck) to days (container / E-House)
Three platforms: on-truck, containerized, E-House
GIS or AIS HV switching, full protection + SCADA
Hydraulic jacking & self-leveling (truck)
ISO 20 / 40 / 45 ft stackable containers
Walk-in E-House with cable basement (permanent)
Weatherproof IP54 / IP55 · −35 to +50 °C
IEC 62271-202 / IEEE C37.121 FAT certified
Ship, rail, or highway transport (oversize permits)

Where a Mobile Substation Earns Its Keep

AIDC Interim Step-Up

Ten containerized gas gensets generate at 10.5 kV. An 80 MVA / 138 kV mobile step-up substation connects them to the utility tie — built in ~20 weeks, energized within hours of arriving on site, then redeployed when the permanent GSU arrives.

Storm & Outage Restoration

Drive to a flooded or fire-damaged utility substation. Bypass the damaged bus with a trailer-mounted substation; restore load within 24 hours while FEMA, crews, and long-lead replacement equipment mobilize.

Planned Maintenance

Replace aging 25- to 40-year-old transformers and GIS without taking the substation off-line. Mobile unit supplies N\u22121 capacity during each phase of the rebuild.

Remote / Construction Sites

Mining, oil & gas, construction camps, and renewable-energy commissioning. Containerized or trailer-mounted substations step up generator voltage to utility tie-in — and leave when the project finishes.

SST — Solid State Transformer

SST — Solid State Transformer

Power-electronic solid state transformers that convert 10 kV AC directly to 240 / 336 / 750 / 800 / 1000 VDC, eliminating two conversion stages in AI data center distribution — including NVIDIA’s 800V HVDC Native standard. Factory-prefabricated cabinets at 840 / 1,680 / 2,520 / 3,360 kVA with busbar interconnect, N+3 internal redundancy, input power factor ≥ 0.99, input current THD ≤ 3%, and system efficiency ≥ 98% (AC–DC) / ≥ 97% (AC–AC). Single cabinet up to 960 kW — 60% smaller footprint than conventional MV–LV–rectifier chains.

840 / 1,680 / 2,520 / 3,360 kVA cabinets
10 kV AC input, 8.5–11.5 kV operating range
240 / 336 / 750 / 800 / 1000 VDC output (selectable, incl. NVIDIA 800V std)
System efficiency ≥ 98% (AC–DC)
Input PF ≥ 0.99, iTHD ≤ 3%
N+3 internal redundancy, distributed control
Battery compatible: Li-ion / VRLA / Ni-Cd
Prefabricated busbar interconnect (no cable tray)
10" color HMI, RS232 / RS485 / Ethernet / dry contacts
IP20 std, IP31 optional; noise < 75 dB @ 1 m

Every Unit. Third-Party Proven.

IEEE C57 (US), IEC 60076 (international), AS 60076 (Australia), GOST (CIS), and EN / CE (EU). Plant-level ISO 9001 / 14001 / 45001 / 50001 / 28000, third-party ESG green factory audit, CNAS-accredited labs, and STRI-compared 10 kV test systems. UL listings on pad-mounted and dry-type lines; short-circuit withstand type-test reports issued with every power-class order; full FAT documentation on every mobile substation.

Get Started

Need Help Selecting the Right Transformer?

Send us your one-line diagram, load spec, or existing nameplate. Our engineers will recommend the right type, sizing, cooling class, fluid selection, and tap configuration within 24 hours.

Preliminary sizing & budget pricing back in 24 hours. One-line diagram or rough specs is enough — we'll fill in the rest.